Furnace Pilot Light Repair Severance CO

When your heat quits on a 12-degree night in Severance, Colorado, you need Furnace Pilot Light Repair Severance CO you can count on. We diagnose why the pilot won't stay lit, replace worn thermocouples and flame sensors, and get your furnace firing again.

Serving Severance and nearby areas.

How big is the pilot light job?

Part replacement

Thermocouple, flame sensor, or igniter swapped and tested.

  1. 1. Relight only Pilot assembly cleaned and relit, flame verified through a full cycle.
  2. 2. Part replacement Thermocouple, flame sensor, or igniter swapped and tested.
  3. 3. System repair Gas valve, control board, or heat exchanger work planned in writing first.
  • 24Services from one local team
  • 15Areas served around Severance
  • Test firstReadings before parts
  • Two cyclesPilot watched through both

What Our Pilot Light Repair Includes

Every Furnace Pilot Light Repair Severance CO visit covers the full diagnostic and the repair itself, plus the safety checks that make sure the furnace is burning clean.

Dependable Furnace Repair across Severance, Colorado

Work order

Furnace Pilot Light Repair
  • Full Pilot Diagnostic: We test the thermocouple or flame sensor with a multimeter, check gas pressure with a manometer, and inspect the control board for fault codes. This is how we find the actual reason the pilot is failing instead of just relighting it.
  • Component Replacement: If a thermocouple, flame sensor, igniter, or gas valve has failed, we replace it on the spot with a part matched to your furnace brand. Common parts for Carrier, Trane, Goodman, and Rheem ride on every truck.
  • Pilot and Burner Cleaning: Dust, rust, and debris clog pilot orifices and burner ports over time. We clean both, which restores a steady flame and often fixes nuisance shutdowns without any parts at all.
  • Combustion and Draft Test: We run a combustion analyzer at the flue and check the draft hood to confirm the furnace is venting properly. A pilot problem sometimes traces back to a blocked flue, and this test catches it.
  • Temperature Rise Check: We measure the temperature rise across the heat exchanger and compare it to the data plate. If it is out of spec, we adjust airflow or flag a duct issue before it becomes a bigger problem.
  • Written Summary: You get a written summary of what we found, what we replaced, and the readings we took. If something else needs attention down the road, it is on the page for you and any future tech.

What the first visit covers

First visit

We test the pilot assembly, gas pressure, and flame signal, then explain what failed and what it takes to fix it.

Pilot light repair at your home

Standing-pilot and modern ignition furnaces in houses across Severance and Weld County.

  • Pilot will not light

    Thermocouple or gas pressure diagnosis on site.

  • Pilot dies overnight

    Flame sensor and draft testing to find the cause.

  • Furnace blowing cold

    Full system check, not just the pilot.

  • Gas smell near furnace

    Leak check and safe shutdown before any repair.

Furnace Pilot Light Repair

Pilot light repair for small business

Unit heaters and rooftop furnaces at shops, offices, and rental properties around Severance.

  • Rental units

    Block scheduling and per-unit written summaries.

  • Small shops

    Unit heater pilot and ignition repair.

  • Offices

    Rooftop furnace pilot and control diagnostics.

Furnace Pilot Light Repair Severance CO Explained

A pilot light that will not stay lit is a symptom, not the problem. We test the parts, find the cause, and verify the fix through two full heating cycles before we leave.

Furnace Pilot Light Repair Severance CO is a diagnostic heating service that restores the standing pilot flame your gas furnace needs to ignite the burners. During a call, a technician checks the thermocouple or flame sensor, tests the gas valve with a manometer, inspects the control board, and confirms the pilot holds steady through a full heat cycle. Most standing-pilot furnaces run on natural gas or propane, and a weak flame is often the first sign of a failing safety component.

Severance sits at 4,800 feet in Weld County, where winter nights regularly drop below 10 degrees and propane furnaces in rural pockets work harder than most. When a pilot light keeps going out in Severance, Colorado, the cause is usually a dirty flame sensor, a cracked thermocouple, or a draft pulling the flame off the orifice. We see this most in older homes near the downtown core and in newer builds off County Road 23.

Severance Furnace Repair Pros — your local Furnace Repair team
What it is
Diagnostic repair of the furnace pilot and ignition system.
When it helps
When the pilot will not light or will not stay lit.
What you get
A working furnace and a written summary of findings.

What Our Pilot Light Repair Process Looks Like

Every Furnace Pilot Light Repair Severance CO call follows the same five steps, whether it is a 20-year-old Bryant or a newer Lennox.

  1. Phone Triage

    When you call, we ask the furnace brand, age, fuel type, and whether the pilot lights at all or dies after a few seconds.

  2. On-Site Safety Check

    The tech shuts off the gas, checks for leaks at the valve and union, and inspects the flue and draft hood. Takes about 10 minutes.

  3. Diagnosis and Testing

    We test the thermocouple or flame sensor with a multimeter, read inlet gas pressure with a manometer, and check the control board for fault codes.

  4. Repair and Relight

    We replace the failed component, clean the pilot orifice and burner ports, then relight the pilot and watch it through two full heating cycles.

  5. Combustion Test and Walkthrough

    Before we pack up, we run a combustion analyzer at the flue, check the temperature rise against the data plate, and show you the readings.

Tools and Methods We Use

Each method answers a different question. Together they leave very little to guess.

Measures inlet and manifold gas pressure to confirm the furnace is getting the fuel pressure it was designed for. Wrong pressure is a common cause of pilot failures.

Tests thermocouple millivolt output and flame sensor microamp signal. These readings tell us whether a safety component is actually failing or just dirty.

Reads oxygen, carbon monoxide, and flue temperature at the vent. Confirms the furnace is burning clean and venting properly after a pilot repair.

A dedicated tester for standing-pilot systems that gives a fast pass or fail on the thermocouple without pulling the assembly apart first.

Lets us look inside the heat exchanger and flue path without disassembly. Catches cracks and blockages that a visual check from outside would miss.

When Severance Homeowners Call Us

  • A homeowner wakes up to a cold house on a January morning and finds the pilot out on an older standing-pilot furnace.

    We dispatch a same-day tech with thermocouples and flame sensors on the truck.

    Homes
  • A propane furnace in a rural Severance property keeps losing its pilot every few days through the winter.

    We test propane gas pressure with a manometer, check the regulator setting, and inspect the flame sensor and thermocouple.

    Homes
  • A property manager with rentals around Weld County needs a reliable pilot light relight service for multiple units.

    We schedule the calls in a block, diagnose each furnace, and send a written summary per unit.

    Businesses
  • A homeowner smells gas near the furnace and the pilot will not light at all.

    We treat it as an emergency, shut off the gas at the valve, and test for leaks at every joint.

    Homes

How Pilot Light Repair Works in Severance

Severance sits at about 4,800 feet in Weld County, and that altitude changes how gas furnaces behave. Standing pilots burn leaner up here, and a thermocouple that would last years at sea level can fail faster in the thinner air.

  • Downtown Severance

    Older homes here often have standing-pilot furnaces that are 15 to 25 years old. Thermocouple and pilot assembly failures are the most common calls we run in this area.

  • Severance East

    Newer construction on the east side tends to have high-efficiency furnaces with hot surface igniters. When those fail, the symptom looks the same as a pilot problem, but the fix is different.

  • County Road 23 corridor

    Rural properties along this corridor often run propane, which is more sensitive to regulator pressure. Pilot failures here frequently trace back to gas pressure rather than the pilot parts themselves.

Severance Furnace Repair Pros serving Severance, Colorado
  • Downtown Severance
  • Severance East
  • County Road 23 corridor
  • Severance Farms area

From problem to finished result.

Slide to compare the photo with an illustrative inspection view. It is generated from the photo, not a measurement.

Furnace Pilot Light Repair in Severance, ColoradoPhoto
  • Standing Pilot Furnace Back Online

    Before: A homeowner in downtown Severance woke up to a 55-degree house and a pilot that would not stay lit. The furnace was a 2004 Bryant standing-pilot unit. Two previous relight attempts had failed within hours.

    After: We replaced the thermocouple, cleaned the pilot orifice, and set gas pressure to spec. The pilot held through two full heating cycles, and the house was back to 68 degrees within 90 minutes of our arrival.

  • Propane Furnace Pilot Stops Dropping Out

    Before: A rural property off County Road 23 had a propane furnace losing its pilot every two to three days. The homeowner had been relighting it manually for three weeks and was ready to replace the furnace.

    After: We found the propane regulator pressure was set for natural gas specs. After adjusting to the correct propane pressure and replacing the flame sensor, the pilot held for the rest of the season with zero dropouts.

  • Rental Unit Heat Restored Same Day

    Before: A property manager in Eaton had a tenant without heat on a Friday afternoon in January. The furnace was a Goodman standing-pilot unit, and the pilot would light but die within seconds.

    After: Our tech diagnosed a failed gas valve and a dirty flame sensor. We replaced both on the same visit, tested combustion, and had the unit heating again by 6 p.m. The tenant stayed in the unit over the weekend.

Pilot Light Problems We Fix in Severance

Most no-heat calls we run in Severance come down to one of a handful of pilot failures.

Ask about yours

  • Pilot light will not stay lit

    The furnace never fires, the house loses heat fast, and in a Severance cold snap pipes can freeze within hours.

  • Furnace pilot light keeps going out in Severance, Colorado

    Intermittent pilot failures are the worst kind because the furnace works just long enough to make you think it is fine.

  • Furnace blowing cold air after pilot lights

    The pilot lights and the burners fire, but the blower never comes on or runs constantly.

  • Furnace banging noise when pilot fires

    A bang or boom at ignition means gas is building up before it lights.

  • Furnace leaking water near the pilot area

    Water around a gas furnace usually means a condensation or flue issue, and it can rust out the heat exchanger if ignored.

Why Severance Homeowners Call Us

A dead pilot light means no heat, and in a Severance January that is not something you can wait out.

Heat Back Same Day

Most pilot light relight calls in Severance finish in 60 to 90 minutes.

Root Cause, Not a Quick Fix

Relighting a pilot without finding why it went out just means it dies again next week.

Safe Combustion Verified

A pilot that will not stay lit can signal a cracked heat exchanger or a blocked flue.

Straight Pricing, No Surprises

Affordable pilot light relight Severance pricing starts with a flat diagnostic fee, and we quote the repair before we touch a wrench.

What you receive

Clear records you can keep and share.

  • Diagnostic findings

    What failed and the readings behind it.

  • Parts replaced

    A list of what was swapped and why.

  • Combustion readings

    Flue and temperature rise numbers on paper.

Before work starts

A plan in writing

Ask for a written scope

10 Years Fixing Pilot Lights in Weld County

Severance Furnace Repair Pros has been working on gas and propane furnaces since 2016, and pilot light failures are one of the most common calls we…

Local Furnace Repair team in Severance

Thermocouple output

Millivolt reading tells us if the thermocouple is weak or failed.

Gas pressure

Manometer reading confirms the furnace is getting the right fuel pressure.

Flame signal

Microamp reading shows whether the flame sensor is reading the pilot correctly.

Are you in our Severance service area?

Type your ZIP or town to check. If yours is not listed, call and ask.

Severance ZIP codes

  • 80650
  • 80546
  • 80550
  • 80610

Towns we serve.

Based in Severance and covering the places around it. Pick one for local details.

View all service areas

What Severance Customers Say

Pilot went out on a Sunday night and the house was down to 58 by morning. Called these guys at 7 a.m. and a tech was here by 10. Turned out to be a bad thermocouple and a dirty pilot orifice. He had both on the truck, had us running in under an hour, and showed me the combustion readings before he left. Fair price, no upsell.
Marcus T.Homeowner, Severance
Our propane furnace kept losing the pilot every few days. Two other shops just relit it and left. Severance Furnace Repair Pros actually tested the gas pressure and found it was set wrong for propane. Adjusted it, replaced the flame sensor, and we have not had a problem since. That was last winter.
Dana R.Homeowner, Windsor
I manage a few rentals around Weld County and pilot calls are constant in winter. These guys are the only ones I call now. They show up when they say, they diagnose properly instead of guessing, and they send me a written summary of what they found. Makes my job a lot easier.
Ken W.Property Manager, Eaton

Frequently Asked Questions

Short answers for the first few minutes. The team can cover the rest.

Still have a question?

Describe what you are seeing and we will point you to the right next step.

(970) 1234567

A thermocouple or flame sensor swap sits at the low end; a gas valve or control board replacement pushes toward the top. The diagnostic fee is flat and we quote the repair before starting, so you know the number before we open a toolbox.

The three most common causes are a worn thermocouple, a dirty flame sensor, and a draft pulling the flame away from the orifice. In Severance, high-altitude air and cold return drafts make the third one more common than most homeowners expect. A technician can test each in about 20 minutes and tell you which one is failing.

Severance Furnace Repair Pros relights standing pilots and repairs the underlying fault across Severance, Windsor, Eaton, Greeley, and the rest of Weld County. We handle natural gas and propane furnaces and carry the common parts on the truck. Call (970) 1234567 and we will get a tech scheduled.

Yes. If your furnace is dead and the house is dropping below 60 degrees, call and we will dispatch the nearest available tech. Same-day Furnace Pilot Light Repair Severance CO is the goal on every emergency call.

Get Your Furnace Pilot Light Repair Severance CO Today

(970) 1234567

No heat is not something to sleep on in a Colorado winter.

Call for Furnace Repair in Severance

Call (970) 1234567 and describe what your furnace is doing. We answer, triage the symptom and give you a two-hour arrival window. Regular hours run 8 a.m. to 6 p.m. Monday through Friday, with emergency coverage for no-heat calls. If you are in ZIP 80650, 80546, 80550 or 80610, you are in our regular service area.

Request a visit

How soon do you need us?

Thanks. Your request is in and the team will follow up shortly.

Call now(970) 1234567